Exercise · level 1 · fixed run
The Willows — Multiple viewpoint effects testing
Frames · Fire Scene Engine
Loading…
T+20 min
Well alight — flames from the opening and making up; black smoke, heavy, hot.
Doctrine-referenced debrief · not an assessment
[1]Incident Commander — Command Performance Review
Safety-critical event: Flashover with BA crews committed at T+20. Unsatisfactory command performance with critical safety or coordination lapses that require structured developmental intervention.
- No explicit Level 3 anticipation recorded. Look ahead: verbalise predicted fire spread and future resource needs before escalation occurs.
- Limited Level 2 understanding evident. Translate observations into operational meaning (e.g. what dark pulsing smoke signifies for entry safety).
- Level 1 Perception active (2 situational observations recorded).
- All identified critical hazards had corresponding mitigating actions recorded.
- Orders judged on their effect: 4 given — 2 sound, 1 wrong for the conditions, 1 not scored.
- Decision controls and cues are not captured from typed orders and are not scored.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Pump Operator.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Police Sergeant 4421 (Met).
- Information from Police Sergeant 4421 (Met) was appropriately incorporated into commander's response.
- Tactical mode lag in Alfa: Mode changed to DEFENSIVE 5m ago, but crews remain committed inside and are NOT yet accounted for. Initiate emergency evacuation roll-call.
- Maintained clear command presence and tactical leadership.
- Active monitoring intervals maintained without decision stagnation.
- Maintained safe span of control (1 sectors).
Key Strengths
- Handled all dynamic roleplay injects and operational messages effectively.
Development & Learning Opportunities
- Safety-critical: Flashover with BA crews committed at T+20 — this overrides the marker average.
- Sector mode contradiction: Tactical mode lag in Alfa: Mode changed to DEFENSIVE 5m ago, but crews remain committed inside and are NOT yet accounted for. Initiate emergency evacuation roll-call.
- Safety warning: No scene access control point (SACP) established to log personnel entering the inner cordon.
- Operational briefing was unstructured — adopt the standard IIMARCH framework (Information, Intent, Method, Risk).
The incident got away — but there’s plenty to take forward.
Developmental reflection — not an assessmentWhat went well
- Good call — monitor at T+0 (“Perform a 360 and establish a water supply”).
- Good call — defensive external at T+10 (“External attack through upstairs window”).
- Every judged decision (2) matched the conditions.
- Gathered information before acting: speak to witness (T+10), fire control update (T+10), consult responsible person (T+10), check ori (T+10).
What to develop
- Questionable — offensive internal at T+15 (“Leave perimeter as it is for now, establish an inner cordon and send in a BA crew to assess conditions”) for the conditions at the time.
- Safety-critical — Flashover with BA crews committed (T+20).
- Flashover with BA crews committed — a safety-critical failure.
- A casualty on the first floor was never found (deceased).
- Property partially saved (damage 23).
Key decision points
- T+00 [monitor · good] “Perform a 360 and establish a water supply”
- T+05 [monitor] “Send a METHANE”
- T+10 [defensive-external · good] “External attack through upstairs window”
- T+15 [offensive-internal · questionable] “Leave perimeter as it is for now, establish an inner cordon and send in a BA crew to assess conditions”
Learning points
- Incident states: Venting fire (T+0).
- Read the warning signs — sealed compartment, hot pulsing smoke, severe fire — before committing crews.
- Send an early METHANE / informative message to set the incident picture.
- With persons unaccounted for, search the fire floor first — “nobody inside” is a claim, not a fact.
Discuss this with the training mentor
Mentor grounded in published UK FRS principles — developmental discussion, not assessment. It cites its sources or reframes as a question.
Incident report
Practice — not a real IRS submission