Exercise complete — open the debrief
Exercise · level 1 · seed 1282163142
Command exercise — Developing fire — day
T+35min
Stage 4 · ResolutionExtinguishedDefensive Wind → from the leftFrames · Fire Scene Engine
Selected view · T+35 minutes is loading…
Loading…
T+35 min
Small fire — smoke issuing, little flame visible from the street; light smoke, light, hot. Damping down.
TimelineT+35 / 35Resolution
Doctrine-referenced debrief · not an assessment
[1]Incident Commander — Command Performance Review
SFJ Awards Level 3 Award in Initial Incident Command in Fire and Rescue ServicesOfqual Ref: 610/0183/1 · Unit 6033 · 65h TQT
Competent operational command meeting UK FRS standards, with sound dynamic risk assessment and structured execution across core incident phases.
Doctrine Score79/100
competent
Situational Awarenessexemplary
85%
- Level 3 Anticipation demonstrated (1 instance(s)). Proactively predicted fire development, resource escalation, or tactical consequences.
- Limited Level 2 understanding evident. Translate observations into operational meaning (e.g. what dark pulsing smoke signifies for entry safety).
- Level 1 Perception active (6 situational observations recorded).
- All identified critical hazards had corresponding mitigating actions recorded.
Decision Makingcompetent
84%
- Orders judged on their effect: 7 given — 5 sound, 0 wrong for the conditions, 2 not scored.
- Decision controls and cues are not captured from typed orders and are not scored.
Interpersonal Communicationexemplary
90%
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Command Support.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Adjacent Shopkeeper.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Safety Officer.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Fire Control.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Pump Operator.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Police Sergeant 4421 (Met).
- Information from Police Sergeant 4421 (Met) was appropriately incorporated into commander's response.
- Rapid, prompt acknowledgement to Safety Officer.
- Response provided, but did not explicitly repeat back critical operational specifics.
- Rapid, prompt acknowledgement to Safety Officer.
- Response provided, but did not explicitly repeat back critical operational specifics.
Teamwork & Coordinationunsatisfactory
50%
- Tactical mode lag in Alfa: Mode changed to DEFENSIVE 10m ago, but crews remain committed inside and are NOT yet accounted for. Initiate emergency evacuation roll-call.
Leadership & Command Presencecompetent
75%
- Maintained clear command presence and tactical leadership.
Personal Resilienceexemplary
90%
- Active monitoring intervals maintained without decision stagnation.
- Maintained safe span of control (1 sectors).
Key Strengths
- Demonstrated proactive Level 3 Anticipation by forecasting fire progression and resource demands.
- Handled all dynamic roleplay injects and operational messages effectively.
Development & Learning Opportunities
- Sector mode contradiction: Tactical mode lag in Alfa: Mode changed to DEFENSIVE 10m ago, but crews remain committed inside and are NOT yet accounted for. Initiate emergency evacuation roll-call.
- Safety warning: No scene access control point (SACP) established to log personnel entering the inner cordon.
- Operational briefing was unstructured — adopt the standard IIMARCH framework (Information, Intent, Method, Risk).
Good stop — the fire was brought under control.
Developmental reflection — not an assessmentWhat went well
- Good call — monitor at T+0 (“Conduct a 360 of the property first”).
- Good call — offensive internal at T+5 (“Make pumps 4, ready BA team for internal attack and search and rescue”).
- Good call — monitor at T+10 (“Establish an inner cordon, cordon off the oxy-acetylene cylinders and ensure fire does not spread near them.”).
- Good call — offensive internal at T+15 (“Continue internal attack with hose reel jets, between the 4 pumps there is plenty of water on scene to get this fire under control”).
- Good call — defensive external at T+20 (“Daisy chain pumps from a working hydrant further down the road to maintain water supply and begin external attack through the smashed window with a 45mm smoothbore”).
- A tasked search located a casualty (T+10).
- Fire extinguished — smoke clearing to reveal the fire damage. Good stop.
- Every judged decision (5) matched the conditions.
- Information confirmed at T+10: the witness (Ms Okafor, neighbour) said “Someone's still inside; I haven't seen them come out” — a search bore it out.
- Information confirmed at T+10: the occupier said “One person unaccounted for — last seen on the first floor” — a search bore it out.
- Property saved (damage 11).
What to develop
Key decision points
- T+00 [monitor · good] “Conduct a 360 of the property first”
- T+05 [offensive-internal · good] “Make pumps 4, ready BA team for internal attack and search and rescue”
- T+10 [monitor · good] “Establish an inner cordon, cordon off the oxy-acetylene cylinders and ensure fire does not spread near them.”
- T+15 [offensive-internal · good] “Continue internal attack with hose reel jets, between the 4 pumps there is plenty of water on scene to get this fire under control”
- T+20 [defensive-external · good] “Daisy chain pumps from a working hydrant further down the road to maintain water supply and begin external attack through the smashed window with a 45mm smoothbore”
- T+25 [monitor] “Extend the safety perimeter due to the gas tanks. Make sure fire is fully suppressed and property is empty of casualties”
- T+30 [monitor] “Continue putting water on the fire and check the rest of the property”
Learning points
- Incident states: Venting fire (T+0) → Under control (T+15) → Extinguished (T+35).
- Send an early METHANE / informative message to set the incident picture.
- Gather information early — speak to the witness, check the ORI, ask Fire Control and the BA crews — and act on what you learn.
Discuss this with the training mentor
Mentor grounded in published UK FRS principles — developmental discussion, not assessment. It cites its sources or reframes as a question.
Incident report